Whether you are in need of military aviation parts, NSN components, or various forms of aerospace and defense parts, Aerospace Store is a single-sourcing solution with over 2 billion product listings readily available for purchase at any time with competitive pricing. You have reached the Request for Quote (RFQ) page for part number WE2555, a Wems Electronics Transformer Gro component we feature that is listed with the NSN 5950003483801 and item name “Transformer Power.” For further identification, part number WE2555 was also specifically produced under CAGE Code 26543 and belongs to Federal Supply Class (FSC) 5950 Coils and Transformers. If you would like to receive specific options for procurement that have been tailored to your unique needs and restrictions alike, we ask that you please fill out and submit the form provided on this page with as much information as you can. Once our team has a chance to receive and review your offered details, a dedicated account manager will be in touch shortly after.
Note : We will not share your information to any third parties.
Items like part number WE2555 and others are all readily available with short lead times, and we boast rigorous quality-assurance practices to guarantee the caliber and reliability of every purchase made on our website. Beyond quality, we are fully committed to customer satisfaction, regularly exceeding industry expectations to ensure that we thoroughly and efficiently address every need. If you happen to be facing a time constraint that demands more specialized fulfillment solutions, please give us a call or email at any time to discuss the options we can provide. We are available around the clock and are always happy to assist, so do not hesitate to reach out for part number WE2555 and other various items of interest.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-348-3801 Item Description: Transformer Power | 5950 | 003483801 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
We2555 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 3.530 INCHES MAXIMUM3.530 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.448 INCHES MAXIMUM ALL MOUNTING FACI" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.010 INCHES MAXIMUM ALL MOUNTING FACI" |
ABMK | OVERALL WIDTH | 2.580 INCHES MINIMUM AND 2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM2.680 INCHES MAXIMUM" |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM 2ND GROUP AND 0.148 INCHES MINIMUM 2ND GROUP AND 0.165 INCHES MAXIMUM 2ND GROUP0.165 INCHES MAXIMUM 2ND GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND WYE-OPEN DELTA AND WYE-WYEWYE-WYE" |
ADAU | BODY HEIGHT | 1.420 INCHES MAXIMUM1.420 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS4 ALL GROUPINGS" |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPTHREADED HOLE 1ST GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPUNTHREADED HOLE 2ND GROUPUNTHREADED HOLE 2ND GROUPTHREADED HOLE 1ST GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT" |
CBBL | FEATURES PROVIDED | W/RECTIFIER AND COLOR CODED LEAD" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP0.138 INCHES 1ST GROUP" |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 230.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 201.00 AC" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC VOLTS NOM" |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
FEAT | SPECIAL FEATURES | VOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARYVOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARY" |
TEST | TEST DATA DOCUMENT | 07187-4010238 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW" |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 3.530 INCHES MAXIMUM3.530 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.428 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.448 INCHES MAXIMUM ALL MOUNTING FACI" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 1.990 INCHES MINIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM ALL MOUNTING FACILITIES SINGLE CENTER GROUP2.010 INCHES MAXIMUM ALL MOUNTING FACI" |
ABMK | OVERALL WIDTH | 2.580 INCHES MINIMUM AND 2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM2.680 INCHES MAXIMUM" |
ABTB | MOUNTING HOLE DIAMETER | 0.148 INCHES MINIMUM 2ND GROUP AND 0.148 INCHES MINIMUM 2ND GROUP AND 0.165 INCHES MAXIMUM 2ND GROUP0.165 INCHES MAXIMUM 2ND GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO SINGLE PHASE SINGLE COMPONENTTHREE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND WYE-OPEN DELTA AND WYE-WYEWYE-WYE" |
ADAU | BODY HEIGHT | 1.420 INCHES MAXIMUM1.420 INCHES MAXIMUM" |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS155.0 DEG CELSIUS" |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS4 ALL GROUPINGS" |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPTHREADED HOLE 1ST GROUP" |
AXGY | MOUNTING METHOD | THREADED HOLE 1ST GROUPUNTHREADED HOLE 2ND GROUPUNTHREADED HOLE 2ND GROUPTHREADED HOLE 1ST GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT7 SECONDARY SINGLE COMPONENT" |
CBBL | FEATURES PROVIDED | W/RECTIFIER AND COLOR CODED LEAD" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES 1ST GROUP0.138 INCHES 1ST GROUP" |
CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 230.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 201.00 AC" |
CWJS | WINDING OPERATING VOLTAGE | 10.50 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY26.20 DC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 33.00 DC VOLTS NOM" |
CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 74.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY" |
FEAT | SPECIAL FEATURES | VOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARYVOLTAGES AND CURRENTS HAVE BEEN RECTIFIED FOR THE FIRST SECONDARY" |
TEST | TEST DATA DOCUMENT | 07187-4010238 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW" |
THSD | THREAD SERIES DESIGNATOR | UNC 1ST GROUP" |
TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD" |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.