If you are in need of NSN parts such as 171040, look no further than Aerospace Store. Owned and operated by ASAP Semiconductor, a leading aerospace and defense distributor, Aerospace Store has access to an inventory of more than two billion new and obsolete parts including Transformer Power and much more.
Anything not in our inventory can be found through our international supply chain network that spans the United States. Additionally, Aerospace Store upholds a strict no China sourcing policy, guaranteeing that each part you buy from us is fully traceable or comes directly from a trusted manufacturer like Voltampere Corp.
Note : We will not share your information to any third parties.
Each of our NSN 5950004829582 parts like 171040 by Voltampere Corp is readily available with short lead times and competitive prices. Aerospace Store boasts a broad selection of in-demand parts from manufacturers such as Voltampere Corp and others. To get in touch with a dedicated account manager, simply submit an RFQ. To do this, enter the part number you want, the quantity needed, and when you need the parts by.
After this, enter some basic contact information and submit. Our team of account managers is standing by and will respond to all RFQ’s in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-482-9582 Item Description: Transformer Power | 5950 | 004829582 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | isc | rnvc | rncc | HCC | MSDS | SADC |
171040 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 5.120 INCHES MINIMUM AND 5.190 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.610 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.640 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.300 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.340 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKW | OVERALL HEIGHT | 7.922 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 4.750 INCHES MINIMUM AND 4.880 INCHES MAXIMUM" |
ABTB | MOUNTING HOLE DIAMETER | 0.249 INCHES MINIMUM SINGLE GROUP AND 0.255 INCHES MAXIMUM SINGLE GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT" |
ADAU | BODY HEIGHT | 6.435 INCHES MINIMUM AND 6.625 INCHES MAXIMUM" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 370.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 197.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 218.40 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 2.40 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 520.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
FEAT | SPECIAL FEATURES | 1 GROUNDED STUD CONNECTED TO CORE AND CASE" |
TTQY | TERMINAL TYPE AND QUANTITY | 17 THREADED STUD" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | OVERALL LENGTH | 5.120 INCHES MINIMUM AND 5.190 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.610 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.640 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.300 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.340 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKW | OVERALL HEIGHT | 7.922 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 4.750 INCHES MINIMUM AND 4.880 INCHES MAXIMUM" |
ABTB | MOUNTING HOLE DIAMETER | 0.249 INCHES MINIMUM SINGLE GROUP AND 0.255 INCHES MAXIMUM SINGLE GROUP" |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT" |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT" |
ADAU | BODY HEIGHT | 6.435 INCHES MINIMUM AND 6.625 INCHES MAXIMUM" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 370.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 197.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 218.40 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 2.40 AC KILOVOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 520.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
FEAT | SPECIAL FEATURES | 1 GROUNDED STUD CONNECTED TO CORE AND CASE" |
TTQY | TERMINAL TYPE AND QUANTITY | 17 THREADED STUD" |